Showing 1–9 of 10 results
-

-

APC UPS_ – Download here
• 10–40 kVA UPS
• With internal batteries (supplied with the UPS)
• For internal batteries*
• For external batteries*
Easy UPS 3M
• 60–200 kVA UPS
• For external batteries*
-

DELTA -UPS-VX Series– Brochure Download
Brand |
Delta |
Input Voltage |
230 Volts |
Configuration |
1 Phase IN – 1 Phase OUT |
Usage/Application |
Industrial |
Display Type |
LCD |
Country of Origin |
Made in India |
Minimum order quantity: 1 Piece
-

Eaton Company brochure download
Key Features of ETO UPS Systems:
Online Topology: Provides the highest level of power quality and protection, ensuring continuous power supply even during power outages.
Double Conversion Technology: Converts incoming AC power to DC and then back to AC, isolating the load from power fluctuations.
Wide Input Voltage Range: Accommodates variations in input voltage, extending battery life and reducing maintenance.
Battery Backup: Provides reliable backup power during power outages, ensuring uninterrupted operation of critical equipment.
Automatic Voltage Regulation (AVR): Corrects voltage fluctuations, preventing damage to equipment.
Frequency Regulation: Maintains a stable output frequency, ensuring compatibility with sensitive equipment.
Cold Start Capability: Can start without external power, providing immediate backup power in emergency situations.
Remote Monitoring and Management: Allows for remote monitoring and control of UPS systems, improving efficiency and reducing downtime.
Intelligent Battery Management: Optimizes battery performance and extends battery life.
-

HITACHI_UPS_Catalogue_ – Download here
Potential Differences Between IP11 and HS11 Series
While both series offer similar core functionalities, there might be differences in:
- Power capacity: HS11 series models tend to offer higher power capacities compared to IP11.
- Efficiency: HS11 series might have higher efficiency ratings.
- Features: HS11 series could include additional features like input power factor correction (PFC) or eco-mode operation.
- Physical dimensions: HS11 models might have larger footprints to accommodate higher power capacities.
Specific Technical Specifications
To obtain precise technical specifications for a particular model within the IP11 or HS11 series, please provide the following information:
- Model number: This is crucial for identifying the exact specifications.
- Output power (kVA or kW): Indicates the UPS’s capacity.
- Input voltage and frequency: Specifies the acceptable input power conditions.
- Output voltage and frequency: Defines the power supplied to the load.
- Battery type and capacity: Determines backup time.
- Dimensions and weight: Important for installation planning.
- Efficiency rating: Indicates energy efficiency.
- Overload capacity: Specifies the UPS’s ability to handle temporary overloads.
-

HITACHI_UPS – Download here
Product Specification
Brand |
Hitachi |
Power System |
10 kVA to 40 kVA |
High input PF |
Less Than O.99 |
Input Current |
THDi Less Than 3 % |
Model |
HS33 |
Product Description
Features:
- High efficiency, up to 96%
- True double-conversion
- Full DSP control technology guarantees high performance
- Wide input voltage range
- Active power factor correction in all phases
- Multi-protection, as temperature, overload, battery under voltage, fan failures, short circuit
- Four circuit breakers, providing full protection when fault happens
- Battery cold start
- Battery management smart charging control, auto maintenance, greatly extend the battery
- life
- Friendly operation interface, high-resolution intelligent LCD screen
- Eco mode operation for energy saving (ECO)
- Emergency power off function (EPO)
- Generator compatible
- SNMP+USB+RS-232 multiple communications
- Adjustable battery numbers
- Maintenance bypass available
-

Brand |
Microtek |
Model Name/Number |
MAX + |
Usage/Application |
Industrial |
Battery Type |
SMF Inbuilt |
Phase |
Single |
Form Factor |
Tower Model |
Country of Origin |
Made in India |
Minimum order quantity: 1 Piece
- Inbuilt OVCD (Over Voltage Cut-Off Device) With Surge Protection.
- Efficient Micro Controller Based, Advanced PFC Technology.
- Static Bypass-improves Reliability.
- Over Temperature Indication & Protection, Generator Compatible.
-

Microteck Legend 1000 VA Catalogue-Download here
Product Brand |
: |
Microtek |
Product I/P Voltage |
: |
140 V ~ 300 V AC |
Product Capacity |
: |
1000 VA |
Product Type |
: |
Line Interactive UPS |
Phase |
: |
Single Phase |
Model Number |
: |
UPS LEGEND 1000 |
Max Load |
: |
600W |
Battery Rating & Qty |
: |
SMF 12V/7 AH X 2 Nos |
-

Microtek Legend 650- Download here
Capacity |
650VA/360W |
Input Voltage Range |
140 V ~ 300 VAC |
Frequency |
50 Hz ± 10% |
Output Voltage |
230 VAC Nominal |
Transfer Time |
Typical 4~8ms |
Waveform (Battery Mode) |
Modified Sine Wave |
Battery Type |
Sealed Maintenance Free |
Charging Time |
6 Hours recover to 90% capacity |
Rating |
SMF 12V /7AH x 1 Battery |
Operating Temperature |
0°C-40°C |
Relative Humidity |
0 to 90% Non-Condensing |
Noise Level |
< 40dB |
Compatibility |
Compatible with Generator |
Dimension |
10 x 28.1 x 14.3 cm |
Weight |
4.46 Kgs |